Secure remote access to industrial systems

The Secomea SiteManager use to securely log in remotely to machines and industrial installations via Internet, without having to open any ports directly in the network.
It's essentially a VPN device for industrial environments allowing you to perform remote maintenance, updates, and diagnostics.

In practice, however, you may want to protect or filter access to specific installations based on individual users or specific tasks.

The intention of this article is to show administrators how to create subdomains and arrange device agents in the domains for limiting user access.

  1. First we right-click the root domain and select “Create Subdomain”:
Secomea
Secomea

We name the new domain “Printer GUI”:

We use the same procedure to create the domain “Printing Access”:

We select the agent “Printer Web GUI” and while holding down the left mouse button, we drag the agent to the domain “Printer GUI”:

We do the same for moving the agent “Printer Print 9100” to the domain “Printing Access”:

Note that the SiteManager itself stays in the root domain.

Was this article helpful?

Leave a Reply

Your email address will not be published. Required fields are marked *

Deze website gebruikt Akismet om spam te verminderen. Bekijk hoe je reactie-gegevens worden verwerkt.